Internal pressure/hydrostatic tests are performed in conditioned water environment. Compliance with the standards ISO 1167, ASTM D 1598, ASTM D 1599. The water distribution into the AL TANK let ± 0,5 – 1 °C, provided by the circulation of water in the tank. Locations of the heaters, the fluid taken and feeding for circulation in the tank are designed with computer simulation and the results have been proved by EU accreditation.
It is suitable for PPRC, PPH, PPB, PE, PVC PE-RT pipes and even composite pipes. Database management, system network.
Internal pressure/hydrostatic tests are performed in conditioned water environment. Compliance with the standards ISO 1167, ASTM D 1598, ASTM D 1599. The water distribution into the AL TANK let ± 0,5 – 1 °C, provided by the circulation of water in the tank. Locations of the heaters, the fluid taken and feeding for circulation in the tank are designed with computer simulation and the results have been proved by EU accreditation.
It is suitable for PPRC, PPH, PPB, PE, PVC PE-RT pipes and even composite pipes. Database management, system network.
Control System
Model | AL-TANK S | AL-TANK M | AL-TANK L | Model | AL-TANK B | Model | Heating Module | ||
Number of Linees | 1-5 | 5-10 | 10-15 | Number of Linees | İsteğe Göre Belirlenir | Temperature Range | Environment Temp. – 95 °C | ||
Internal Length | 1,2 m | 1,6 m | 2,1 m | Internal Length | İsteğe Göre Belirlenir | Sensitivity | ±0,1°C | ||
Outer Length | 1,5 m | 1,9 m | 2,4 m | Outer Length | İç Ölçülere Bağlı Olarak Belirlenir | Accuracy | ±1°C | ||
Internal Width | 1,0 m | 1,0 m | 1,1 m | Number of Hanger Rails | İsteğe Göre Belirlenir | Resolution | ±0,1°C | ||
Outer Width | 1,4 m | 1,5 m | 1,6 m | Automatic Cap | ○ | Data Display | Tank Panosundan | ||
Internal Height | 1,2 m | 1,2 m | 1,2 m | Heat Isolation | ● | ||||
Outer Height (Cap Closed) | 1,55 m | 1,6 m | 1,6 m | Water Discharge Valve | ● | Available ● Optional ○ Not Applicable ▬ | |||
Outer Height (Cap Opened) | 2,2 m | 2,3 m | 2,3 m | Water Level Sensor | ● | ||||
Number of Hanger | 1-3 | 3-6 | 4-8 | Water Circulation Pump | ● | Model | COOLING MODULE | ||
Automatic Cap | ● | ● | ● | Heating Module | ○ | Temperature Range | 20 °C -Environment Temp. | ||
Heat Isolation | ● | ● | ● | Cooling Module | ○ | Sensitivity | ±0,1°C | ||
Water Discharge Valve | ● | ● | ● | Material | 304 Paslanmaz Çelik | Accuracy | ±1°C | ||
Water Level Sensor | ● | ● | ● | Control Panel | ● | Resolution | ±0,1°C | ||
Water Circulation Pump | ● | ● | ● | Standarts | ISO 1167, ASTM D 1598, ASTM D 1599 | Data Display | Tank Panosundan | ||
Heating Module | ○ | ○ | ○ | Air Pressure | 6-8 Bar | ||||
Cooling Module | ○ | ○ | ○ | Available ● Optional ○ Not Applicable ▬ | |||||
Material | 304 Paslanmaz Çelik | Available ● Optional ○ Not Applicable ▬ | |||||||
Control Panel | ● | ● | ● | ||||||
Standarts | ISO 1167, ASTM D 1598, ASTM D 1599 | ||||||||
Air Pressure | 6-8 Bar | 6-8 Bar | 6-8 Bar | ||||||
Available ● Optional ○ Not Applicable ▬ |
Support