Water Tank

Internal pressure/hydrostatic tests are performed in conditioned water environment. Compliance with the standards ISO 1167, ASTM D 1598, ASTM D 1599. The water distribution into the AL TANK let ± 0,5 – 1 °C, provided by the circulation of water in the tank. Locations of the heaters, the fluid taken and feeding for circulation in the tank are designed with computer simulation and the results have been proved by EU accreditation.

It is suitable for PPRC, PPH, PPB, PE, PVC PE-RT pipes and even composite pipes. Database management, system network.

Internal pressure/hydrostatic tests are performed in conditioned water environment. Compliance with the standards ISO 1167, ASTM D 1598, ASTM D 1599. The water distribution into the AL TANK let ± 0,5 – 1 °C, provided by the circulation of water in the tank. Locations of the heaters, the fluid taken and feeding for circulation in the tank are designed with computer simulation and the results have been proved by EU accreditation.

It is suitable for PPRC, PPH, PPB, PE, PVC PE-RT pipes and even composite pipes. Database management, system network.

 

  • Zero steam leakage, energy saving with double layer insulation, minimum operating cost and water loss.
  • Double safety control for instant temperature change.
  • Automatic filling with water level control.
  • Safety Discharge Duct for High level water
  • Bottom discharge
  • Folding lid with remote / direct control
  • Safe operation
  • High performance for water temperature disribution with ideal balancing circulation
  • Usage with glycol water up to 105 °C
  • Nearly up to ± 0,5 °C in-tank temperature distribution
  • Applicable to any dimensions
  • Positioning and traveling hanger system of test sample with End Caps inside the tank

Control System

  • Fast data transfering 400 Hz
  • 5.4 -10 ” PLC Touch Screen (4.2″, 7″, 10″) panel application.
  • 17 – 62 ” Touch Screen PC Panel
  • Real-time temperature measurement up to 4 points
  • Successfull standard and accreditation requirements
  • Connection to main pressure / hydrostatic test machine
  • Frame around inner stainless cabinet (damage prevention)
  • 1.2 mm outer coating
  • Pneumatic cap drive system
  • Wheel and fixing possibility
  • Design without heat bridge
  • Special cover gasket
  • 1.5 mm up to 3 mm inside layer thickness.
Model AL-TANK S AL-TANK M AL-TANK L Model AL-TANK B Model Heating Module
Number of Linees 1-5 5-10 10-15 Number of Linees İsteğe Göre Belirlenir Temperature Range Environment Temp. – 95 °C
Internal Length 1,2 m 1,6 m 2,1 m Internal Length İsteğe Göre Belirlenir Sensitivity ±0,1°C
Outer Length 1,5 m 1,9 m 2,4 m Outer Length İç Ölçülere Bağlı Olarak Belirlenir Accuracy ±1°C
Internal Width 1,0 m 1,0 m 1,1 m Number of Hanger Rails İsteğe Göre Belirlenir Resolution ±0,1°C
Outer Width 1,4 m 1,5 m 1,6 m Automatic Cap Data Display Tank Panosundan
Internal Height 1,2 m 1,2 m 1,2 m Heat Isolation  
Outer Height (Cap Closed) 1,55 m 1,6 m 1,6 m Water Discharge Valve Available ● Optional ○ Not Applicable ▬
Outer Height (Cap Opened) 2,2 m 2,3 m 2,3 m Water Level Sensor
Number of Hanger 1-3 3-6 4-8 Water Circulation Pump Model COOLING MODULE
Automatic Cap Heating Module Temperature Range 20 °C -Environment Temp.
Heat Isolation Cooling Module Sensitivity ±0,1°C
Water Discharge Valve Material 304 Paslanmaz Çelik Accuracy ±1°C
Water Level Sensor Control Panel Resolution ±0,1°C
Water Circulation Pump Standarts ISO 1167, ASTM D 1598, ASTM D 1599 Data Display Tank Panosundan
Heating Module Air Pressure 6-8 Bar  
Cooling Module   Available ● Optional ○ Not Applicable ▬
Material 304 Paslanmaz Çelik Available ● Optional ○ Not Applicable ▬
Control Panel
Standarts ISO 1167, ASTM D 1598, ASTM D 1599
Air Pressure 6-8 Bar 6-8 Bar 6-8 Bar
 
Available ● Optional ○ Not Applicable ▬

 

Quote Request Screen

Your requests via the form have been canceled due to a technical error. Your requests are not reaching us. Please send your request to our e-mail address sales2@alarge.com.tr in our contact heading.